Hot Sale 3mm+2ppm Distance Accuracy Ruide Disteo 23 Optical Theodolite

Product Details
Application: Level Control
Brand: Ruide
Angle Accuracy: 2"
Gold Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (16)
  • Hot Sale 3mm+2ppm Distance Accuracy Ruide Disteo 23 Optical Theodolite
  • Hot Sale 3mm+2ppm Distance Accuracy Ruide Disteo 23 Optical Theodolite
  • Hot Sale 3mm+2ppm Distance Accuracy Ruide Disteo 23 Optical Theodolite
  • Hot Sale 3mm+2ppm Distance Accuracy Ruide Disteo 23 Optical Theodolite
  • Hot Sale 3mm+2ppm Distance Accuracy Ruide Disteo 23 Optical Theodolite
  • Hot Sale 3mm+2ppm Distance Accuracy Ruide Disteo 23 Optical Theodolite
Find Similar Products

Basic Info.

Model NO.
Ruide Disteo 23
Distance
300m
Distance Accuracy
3mm+2ppm
Type
Alphanumeric Keyboard
Dimmension
165*160*340
Weight
4.7kg
Model No
Disteo 23
After-sales Service
Yes
Warranty
1 Year
Accuracy
2"
Vertical Lines
None
Horizontal Line
None
Transport Package
1 Piece Packed in 1 Inner Carton
Specification
Size: 47cm*40cm*28cm Weight: 9kg
Trademark
RUIDE
Origin
Shanghai China
HS Code
9015800090
Production Capacity
10000 Pieces/ Year

Product Description

PRODUCT DESCRIPTION
Hot Sale 3mm+2ppm Distance Accuracy Ruide Disteo 23 Optical Theodolite

KEY FEATURES
*300m distance range with Prism, with 3mm+2ppm distance accuracy
*2" Angle Accuracy

*Distance /Axes Stake-out

*2.7 inches LCD screen with Alphanumeric keyboard

PRODUCT SHOW
Hot Sale 3mm+2ppm Distance Accuracy Ruide Disteo 23 Optical Theodolite
Hot Sale 3mm+2ppm Distance Accuracy Ruide Disteo 23 Optical Theodolite
Hot Sale 3mm+2ppm Distance Accuracy Ruide Disteo 23 Optical Theodolite
Hot Sale 3mm+2ppm Distance Accuracy Ruide Disteo 23 Optical Theodolite
Hot Sale 3mm+2ppm Distance Accuracy Ruide Disteo 23 Optical Theodolite
Hot Sale 3mm+2ppm Distance Accuracy Ruide Disteo 23 Optical Theodolite
PRODUCT SPECIFICATION

DISTANCE MEASUREMENT
Range 300m
Accuracy  ±(3mm+2ppm ×D) 
Measuring Time continuous: 0.35s, fine: 1.5s
Atmosphere Correction Manual input, outo correct
Prism Constant Manual input, outo correct
ANGLE MEASUREMENT
Type Absolute encoding
Detection Method H: 2 sides, V: 2 sides
Min, Reading  1"
Accuracy 2"
TELESCOPE
Tube Length 155mm
Image Erect
Magnification 30×
Stadia Accuracy ≤0.40%/L
Field of View 1°30'
Resolving power 3"
Minimum focusing 1.5m
Effective Aperture 40mm
COMPENSATOR
Type single axis
Working range 3'
Accuracy 3"
VIAL
Plate Vial 30"/2mm
Circular Vial 8'/2mm
LASER TUBE
Wave length 635±20nm
Class II laser
Spot Diameter ≤5mm/100m
Axis Error ≤10"
LASER PLUMMET 
Accuracy 31.5mm
Spot Diameter 32.5mm
Length 635±20nm
Class II laser
DISPLAY UNIT
2.7 Inches, 160*96dot
4 lines displays
POWER SUPPLY
Working Temperature -20ºC~+50ºC
Working Time 8hrs
Weight & Dimmensions  4.7kg, 165mm*160mm*340mm
Battery Voltage DC, 7.4V
Battery Type Rechargeable Li-on Battery

PACKING & SHIPPING


Hot Sale 3mm+2ppm Distance Accuracy Ruide Disteo 23 Optical Theodolite
PAYMENT
 

Hot Sale 3mm+2ppm Distance Accuracy Ruide Disteo 23 Optical Theodolite

COMPANY INFORMETION

Shanghai Hexin Survey Instrument Co., LTD has 8 years' experience in geodetic surveying and cadastration surveying, we are a professional and leading enterprise in the surveying industry in MainlandChina. We specialize in the R&D and manufacturing and sales of all kinds of surveying products, including total station, electronic theodolite, electronic distance meter, automatic level, laser level, reflector prism, surveying  accessory, GPS receiver, mapping software, etc.The marketing model advocated by us is not a simple sense of "selling products", instead, pre-sales service, services  during operation and after-sales service are integrated in entire operating activities. It makes the customers feel that they purchased not only a commodity, but also a professional service.We welcome new and old customers from all walks of life to contact us for future business relationships and achieving mutual success!



Hot Sale 3mm+2ppm Distance Accuracy Ruide Disteo 23 Optical Theodolite

FAQ

Q:How to turn off voice broadcast of receiver?
A: a. Enter the WEBUI, find the voice switch in the settings page and turn it off.

b. Controller Software→Device→Device Setting, turn off the "enable voice", and click"ok"

Q: Can the base station and rover station be interchangeable?
A: The difference between the rover station and the base station is that the accessories are different, the function and hardware configuration are the same.You can use the controller to choose the working mode of the device and set it as the base station or rover station.

Q: What is CORS?
A: CORS is called a continuous operating reference station system. It can be understood as a bas e station that is erected at a fixed known point and works continuously for 24 hours and sends its own data to a specific 
serverthrough the network. The use of CORS operation eliminates the need for a base station, and CORS is equivalent to a base station in a normal network operation.

Hot Sale 3mm+2ppm Distance Accuracy Ruide Disteo 23 Optical Theodolite
 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now